Industrial Insulation Standard

Calculation specimen measurement specifications for equipment a

CINI 8.6.02.1 | 2007-10-01
Measurement specification: Drawing CINI 8.5.01 Equipment in m²
Componentfactoreq.m²
Shell      
( 3100 × 6000 + 800 × 500 ) 59,66 1,0 59,66
       
Dome head      
( 3100 x 500 +  ¼ x 3100² ) 12,41 2,5 31,03
Endcap      
( 3100 x 500 + ¼ x 3100² ) 12,41 2,0 24,82
       
Nozzle      
× ¼ × 800² 0,50 1,5 0,75
       
Manhole24"      
( 710 × 380 + ¼ × 710² ) 1,24 2,5 3,10
[24" 2 x insulation thickness = 710]      
Accounted for seperately
Cut out + coverplate 24" manhole
Cut out + T-piece 800mm
Supports 2 stuks
   
p.m.
p.m.
p.m.
      119,36